Packing: Carton
Standard: FDA/CE/ISO13485/ISO9001
Productivity: 1000PCS/Month
Unit Price/Payment: T/T
HS Code: 9018193000
Trademark: Worldhealthmed.com
Origin: China
Min. Order: 1set
Transportation: By Air Or By Sea
Export Markets: North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe |
Product Description
WH-2800 central monitoring system
Description:
Simultaneous display with multi 17" monitors
Parameters:
Display
1. Simultaneous display with multi 17" monitors
2. Each screen can display 8 bedside monitor's information with at least 3 kinds of display mode
3. Display of multi waveforms (ECG, RESP, PLETH, CO2, IBP^) and multi parameters (HR, ST, SpO2, PR, RR, TEMP, SBP, DBP, MAP, 4.72-hours trend storage and printable information for each patient
5. ECG waveform storage with printable information
Setup and Alarm
1. Operating menu with multi-language selection
2. Alarm limit, switch and status of each monitor can be setup by central monitoring system
3. Central monitoring system can be setup its own audio and visual alarm limit
Control
1. ECG lead of each monitor can be changed in central monitoring system
2. NIBP measurement on each monitor can be controlled by central monitoring system
Communication
1. Support long distance monitoring, diagnosis and software upgrade
2. Adaptive network connection for RJ45, Ethernet or RS-232C
3. Wireless and /or Wire networking
|
1.Non-invasive blood pressure |
2. Temperature |
|
|
Measurement type: |
Measurement range:25.0ºC-45.0ºC |
|
|
adult, pediatric, neonate |
|
|
Measurement |
Systolic |
4.0 - 37.0 kPa |
Accuracy: ± 0.1 ºC |
|
|
Diastolic |
1.3 - 33.0 kPa |
|
|
range: |
Mean |
2.6 - 35.0 kPa |
|
|
Accuracy : ± 0.4 kPa or ± 2% |
Resolution: 0.1 ºC |
|
|
Resolution: 0.1 kPa |
response time: ≤ 3 min. |
|
|
Protection: over pressure |
|
|
|
3. ECG |
4. Respiration Rate |
|
|
Input: 5 wires ECG cable |
Measurement range: 0 - 120 BPM(adult) |
|
|
Lead section: |
Accuracy: ± 1 BPM or 5 % |
|
|
I,II,III/ aVR, aVL, aVF/ V |
|
|
Gain(mm/mV): |
Resolution: 1 BPM |
|
|
1/4, 1/2, 1, 2, 4 |
|
|
Frequency response: |
Diagnosis |
0.05 - 100Hz |
5. CO2 |
|
|
Monitor |
0.5 - 40 Hz |
|
|
Surgery |
1.0 - 25 Hz |
|
|
Sweep speed (mm/sec): |
Measurement range: |
|
|
12.5, 25, 50 |
0 %-10.0 % (ins CO2 and et CO2) |
|
|
Heart rate range: 30-254 BPM |
Accuracy: |
|
|
± 2 mm Hg (<5 % Measurement value) |
|
|
Heart rate accuracy: ± 1 % |
10 % (>5 % Measurement value) |
|
|
ST segment deviation analysis: |
6. Pulse oximetry |
|
|
-0.8~+0.8mV |
|
|
ST accuracy: ±0.02mv |
SpO2 measurement range: 0 - 100 % |
|
|
Invasive blood pressure |
Resolution: 1 % |
|
|
Measurement range: |
Pulse measurement range: 30- 254BPM |
|
|
0~40kPa (0~300mmHg) |
|
|
Channel: 2 channel |
Accuracy: ± 2 % |
|
|
Transducer sensitivity: 5MV/V/mmHg |
Resolution: 1 BPM |
|
|
Unit display: kPa or mmHg selectable |
|
|
|
|
7. Environment |
|
|
8. Power requirements |
|
Operation |
Storage |
|
|
Input: 98~260 V AC, 50/60Hz |
Temperature |
0.5 - 40 ºC |
-20 - 50 ºC |
|
|
Consumption: ≤ 80VA |
Relative humidity |
≤ 80% |
≤ 90% |
|
|
|
|
|
|
9. Safety standard: IEC 60601-1 |
|
|
|
Quality System: ISO13485: 2003 |
|
|
|
|
|
|
|
CE approved |
|
|
|