Standard: CE/ISO13485/ISO9001
Productivity:  1000PCS/MONTH
Trademark:  Worldhealthmed.com
Origin:  China
Export Markets:  South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

Product Description
Infusion Pump (WH-SIP1200)

CHARACTERISTICS
Compatible with IV sets of any Brand with high accuracy.
Automatical calibration for IV sets of any Brand.
Three working modes: Drop counting control, Rate control and time control mode.
8 Hours internal battery life in high capacity.
Has a unique color LCD and an internal battery with a high capability.
Swith between ml/h and drops/min freely.
Three levels of alarm volume: High, medium and low.
Three levels of Occlusion pressure: High, medium and low.
KVO function: When finish the total volume of an infusion, the pump will alarm and enter KVO state.

SPECIFICATIONS
Controls:
Drop counting and adjusting the delivery rate automatically
Pump Type: Peristaltic finger
Applicable IV Sets:
Compatible with IV sets of any standard(including lucifugal IV sets)
Accuracy:
≤ 25drop/min: ± 2%, >25drop/min: ± 3% (With the drop counting control mode)
± 5% (With the rate control mode after the correct calibration)
Delivery Rate Range:
1~400drop/min(1drop/min step)
1.0ml/h~1200ml/h (1.0ml/h~99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step)
Delivery Time Range: 1min~1999min (1 min step)
Volume Limit Range: 0~9999ml (1 ml step)
Total Volume Range: 1~9999ml (1 ml step)

Rapid injection: 600ml/h
KVO Rate: 600ml/h
KVO Rate:
W hen the delivery rate≤ 10ml/h, KVO is 1 ml/h. O therwise KVO is 3ml/h.
Alarms:
Air-in-line, Infusion complete when limited volume has been set, Empty container, Occlusion, Door is open, waitting time Over, No drop been detected, Operational errors, Low battery, other device failures.
Power Supply:
AC power supply: AC 100 to 240V± 10%, 50/60Hz;
Internal LI Battery: 11.1V, 2000mAh. 8 Hours of continous operation on a new fully charged battery with the rate of 20 drops/min.
Power Consumption: ≤ 25VA
Safety level: ClassI, Type BF
Dimensions: 130mm(L)× 200mm(W) × 230mm(H)
Net Weight: Approximately. 2.5kg
Operating Conditions: Ambient temperature: 5 to 40 centigrade Relative humidity: 20 to 90%
Storage Conditions: Ambient temperature: -10 to 55 centigrade Relative humidity: 10 to 90%
Accessories: AC power line, Operational manual